工业锅炉给煤设备冷渣器的检查及注意事项
2013/7/29 16:43:37

Industrial coal boiler feed equipment cold slag of examination and matters needing attention1, gas boiler, coal feeder flashboard flexible switch, can be closed tightly. (gas boiler | | qinghai qinghai qinghai coal boiler boiler company)2, no impurities in the coal feeder, idling running, no sound, is in the standby state (no-load running for 15 to 20 minutes), respectively.3, coal you have plenty of coal. (gas boiler | | qinghai qinghai qinghai coal boiler boiler company)The check for industrial boiler cold slag and the matters needing attention1, check whether cold slag machine cooling water inlet pressure in the specified value (0.2 0.8 Mpa).After 2, smooth running, slowly open the slag valve. (gas boiler | | qinghai qinghai qinghai coal boiler boiler company)3, according to the operation need to adjust the cylinder speed, meet the requirements of discharge amount, adjust cooling water at the same time, to ensure the discharge temperature.4, check the lubrication of rotating equipment is normal.

Note:1, if encounter accident has cooled slag is through the emergency discharge, without affecting the normal operation of boiler. (gas boiler | | qinghai qinghai qinghai coal boiler boiler company)2, the runtime must water first, and then, finally opened the door of slag, when stop the step, by contrast, at the same time shall confirm the direction of rotation.

When 3, downtime, should first close the discharge door, then the device to run at least 30 minutes or without slag discharge, may stop. 1 hour and rear can close the gate, also can be normally open.4, long-term outage can be through the drainage water in cylinder body drainage of the goalkeeper. (gas boiler | | qinghai qinghai qinghai coal boiler boiler company)

青海华信锅炉有限公司|青海燃煤锅炉|青海燃气锅炉|青海锅炉公司|青海哪个品牌锅炉好
   工业锅炉给煤设备冷渣器的检查及注意事项
    1、燃气锅炉给煤机插板开关灵活,能严密关闭。    (青海燃煤锅炉|青海燃气锅炉|青海锅炉公司)
    2、给煤机内无杂物,空转运行正常,无异音,处于备用状态(分别空载运行15-20分钟)。
    3、煤仓内有足够的存煤量。            (青海燃煤锅炉|青海燃气锅炉|青海锅炉公司)
工业锅炉冷渣器的检查及注意事项
  1、检查冷渣器冷却水进口水压是否在规定值(0.2-0.8Mpa)。
  2、机器运转平稳后,缓缓打开除渣阀。    (青海燃煤锅炉|青海燃气锅炉|青海锅炉公司)
  3、按运行需要调整筒体的转速,达到要求的排渣量 ,同时调整冷却水量,以保证排渣温度。
  4、检查转动设备的润滑是否正常。
  注意事项:
  1、若遇有冷渣器事故时可通过紧急排渣,而不影响锅炉正常运行。      (青海燃煤锅炉|青海燃气锅炉|青海锅炉公司)
  2、运行时一定要先通水,然后再转机,最后打开渣门,停机时则步骤相反,同时应确认旋转方向。
  3、停机时应先关闭排渣门,然后使设备至少再运行30分钟或无渣排出,方可停机。1小时后方可关闭水门,也可常开。
  4、长期停用可通过排水门将筒体内的存水排掉。   (青海燃煤锅炉|青海燃气锅炉|青海锅炉公司)